Description
WaterMaster's performance adheres to the most stringent global industry standards and is certified to key international approvals. Proven in the toughest applications, Its rugged, robust and buryable sensors eliminate the need of expensive meter chambers. Thereby, WaterMaster flowmeters provide a long, productive and maintenance-free asset life. Take advantage of its innovative and versatile attributes to achieve interoperability within a wide range of asset management systems.
Datasheet
FEW315 - WaterMaster FEW315 Electromagnetic Flowmeter system, full bore, DN 10... DN 600 (3/8 ... 24 in.), integral mount
Bore Diameter |
150 |
DN 150 (6 in.) |
Liner Material |
H |
Hard rubber |
Electrode Design |
1 |
Standard |
Measuring Electrodes Material |
S |
Stainless steel 316 |
Grounding Accessories |
4 |
2x Potential Equalizing Rings (Stainless Steel) |
Process Connection Type |
A1 |
Flanges ANSI / ASME B16.5 / 16.47 series B Class 150 |
Process Connection Material |
B |
Carbon steel |
Usage Certifications |
1 |
Standard (without PED) |
Calibration Type |
A |
Standard factory calibration |
Temperature Range of Installation / Ambient Temperature Range |
1 |
Standard design / -20 ... 60 °C (-4 ... 140 °F) |
Name Plate |
A |
Adhesive label |
Signal Cable Length and Type |
0 |
Without signal cable |
Explosion Protection Certification |
G |
FM Cl. 1 Div. 2 |
Protection Class Transmitter / Protection Class Sensor |
1 |
IP 67 (NEMA 4X) / IP 67 (NEMA 4X), integral |
Cable Conduits |
B |
NPT 1/2 in. |
Power Supply |
3 |
100 ... 230 V AC, 60 Hz |
Input and Output Signal Type |
A |
HART + 20 mA + Pulse + Contact output |
Configuration Type / Diagnostics Type |
1 |
Parameters set to factory defaults / Standard diagnostic functions activated |
Documentation Language |
M5 |
English (standard) |
Verification Type |
V3 |
VeriMaster |
Potable Water and Food & Beverage Approvals |
CWM |
NSF material approval |
Number of Testpoints |
T3 |
3 Points |
|
Specifications
Instrument Warranty Subject to Manufacturer.